Networking & Data

Data Center Design,
Build & Management

From greenfield builds to retrofit upgrades — we engineer data centers that meet Tier II–III standards with precision cooling, redundant power, and structured cabling that scales.

50+
Data Centers Built
Tier III
Design Standard
N+1
Power Redundancy
99.99%
Target Availability

Complete Data Center Solutions

From 10-rack server rooms to Tier III enterprise facilities — precision engineered for availability, efficiency, and scale.

Raised Floor & Containment

Hot/cold aisle containment, raised access flooring (600mm standard), seismic bracing, and anti-static tiling for optimal airflow management and equipment protection.

Precision Cooling

In-row, perimeter, and overhead cooling from Schneider, Vertiv, and Stulz. CFD thermal modeling for airflow optimization and PUE reduction below 1.5.

Power & UPS Systems

Redundant UPS configurations (N+1, 2N), PDUs, ATS, and generator integration. Scalable from 10kVA to 500kVA+ per rack row with full bypass capability.

Structured Cabling

TIA-942 compliant copper and fiber cabling. Top-of-rack, end-of-row, and middle-of-row architectures with full labeling, documentation, and test certification.

Environmental Monitoring

DCIM sensors for temperature, humidity, water leak, smoke, and power. Real-time dashboards with automated alerting and historical trending for proactive management.

Physical Security

Biometric access control, CCTV surveillance, man-trap entries, and rack-level electronic locks. Full audit trail and visitor management for compliance.

Every Critical Infrastructure Environment

From enterprise server rooms to carrier-neutral colocation — we build data centers that meet your uptime, compliance, and capacity requirements.

Enterprise Server Rooms
Colocation Facilities
Telecom Data Centers
Hospital Data Centers
Banking & Financial
Government Facilities
ISP / Carrier Neutral
Edge / Micro Data Centers
Technical Specifications
Tier StandardTier II / Tier III (TIA-942)
Cooling CapacityUp to 25kW per rack
UPS ConfigN+1 or 2N redundancy
Floor Loading12kN/m² raised floor
PUE Target<1.5
Fire SuppressionFM-200 / Novec 1230
BrandsSchneider · Vertiv · APC · Panduit

Precision from Design to Deployment

Every data center we deliver is engineered to your power density, cooling load, and compliance requirements — no compromises on availability or efficiency.

Requirements & Feasibility

Power capacity analysis, cooling load calculation, space planning, and compliance requirements mapping before any design work begins.

Design & Engineering

CAD floor plans, electrical single-line diagrams, CFD cooling models, structured cabling schematics, and full bill of materials for client approval.

Build & Commissioning

Civil works, raised floor installation, power/UPS deployment, precision cooling commissioning, cabling installation and certification testing.

Handover & DCIM

Environmental sensor deployment, DCIM dashboard setup, staff training, as-built documentation handover, and preventive maintenance schedule.

The Region's Data Center Engineering Partner

50+ data centers built across the UAE and Egypt — from 10-rack server rooms to Tier III enterprise facilities with 99.99% availability targets.

Tier III Design Expertise
Our DC engineers design to TIA-942 standards with full redundancy modeling and fault-tolerance testing before a tile is laid.
Vendor-Agnostic Specification
We spec Schneider, Vertiv, APC, and Panduit based on your requirements and budget — not on vendor incentives or partnerships.
CFD Thermal Modeling
Computational fluid dynamics analysis ensures optimal cooling before a single raised floor tile is installed — no hotspots at go-live.
Full Lifecycle Support
AMC contracts covering UPS battery replacement, cooling servicing, firmware updates, and 24/7 monitoring from design through decommission.

Planning a Data Center Project?

Get a free feasibility assessment from our DC engineering team. We design, build, and maintain — end to end.